Ferrules

Copper Sleeve (NP = Nickel Plated)

CODE FOR WIRE SIZE MM FOR WIRE SIZE IMP BORE *1 LENGTH BEFORE SWAGING BITES PER SLEEVE (MIN) *2
CP-105 1.5 1/16” 4.9 8 2
CP-115P 1.6 1/16” 4. 8.8 2
CP-115S 1.5 1/16” 4.9 8.8 2
CP-120 2 5/16” 4.9 9 2
CP-115NP 2 5/64” 4.9 9 2
CP-125 2.5 3/32” 6 10 2
CP-125NP 2.5 3/32” 6 10 2
CP-130 3 1/8” 7.3 13 2–3
CP-130NP 3 1/8” 7.3 13 2–3
CP-130S 3 1/8” 7.3 13 2–3
CP-140 4 5/32” 9.1 16 2–3
CP-140NP 4 5/32” .1 16 2–3
CP-1140S 4 5/32” 9.1 16 2–3
CP-150 5 3/36” 10.9 18 2–3
CP-15NP 5 3/36” 10. 18 2–3
CP-150S 5 3/16” 10.9 18 2–3
CP-160 6   12.7 20 3
CP-164   1/4” 12.7 20 3
CP-164NP   1/4” 12.7 20 3
CP-180 8 5/16” 17 25 3
CP-180NP 8 5/16” 17 25 3
CP-199 10 3/8” 19 27 3
  • * 1 Bore = Dia of cavity in the pressing tool or die used for pressing.
  • * 2 = When using CP hand tool

Aluminium Sleeves

CODE FOR WIRE ROPE BORE LENGTH BEFORE SWAGING BITES PER SLEEVE  
CP-105A 1.5 4.9 8 2  
CP-125A 2.5 6 10 2  
CP-132A 3.2 (1/8”) 7.3 13 2–3
CP-132AS 3.2 (1/8”) 7.3 13 2–3
CP-135A 3.5 (1/8”) 7.3 13 2–3
CP-140A 4 9 16 2–3  
CP-150A 5 10.9 18 2–3  
CP-160A 6 12.7 20 3  

Copper Sleeves for Fibre Rope

CODE USE TOOL FOR ROPE BORE LTH BEFORE SWAGING BITES PER SLEEVE
CP-140R CP-763 4mm 6.9 6 1
CP-160R CP-775 6mm 9.1 8 1
CP-180R CP-775 8mm 10.9 8 1
CP-110R CP-778 10mm 12.8 10 2

NOTE: For best results 2 sleeves should be used for each eye swage when using fibre rope.

Talurit™ Splicing System

Table of sizes for Stainless Steel ferrules

table image

*Available on request.

Ferrules have been validated according to TALURIT™ splicing system.

Note! We do not guarantee strength of slings for lifting activities made of INOXferrules.

A termination performed according to our instructions will normally withstand a tensile strength of 90% of the minimum-breaking load (MBL) of the wire rope. Verifying tests must be done in order to find out the strength.

Wire rope: Above table applies to stainless steel single layer wire ropes with round strands and rope grade 1570.

For higher tensile grade and higher Fill factor, please contact our Technical Department.

Please refer to TALURIT™ “Ferrule Securing Instructions” for further information.

f = Fill factor, is the ratio between the sum of the nominal metallic cross-sectional areas of all the wires in the rope and the circumscribed area of the rope based on its nominal diameter.

C = Nominal metallic cross-sectional area factor of the rope.

Looking for prices?